Free ICC B2 flashcards

12 flashcards from the Building Planning domain. Read the front, show the answer, then grade yourself. Cards you miss come back sooner when you return to this page. No signup.

0 due today12 to learn12 cards

Flashcard · Building Planning

What decides whether a rated wall is built right?

Print these cards (PDF) · cut-out sheets: print double-sided, flip on the long edge

Send these free cards to a coworker.

The course has 100 cards with spaced review.It also adds every question you miss to your deck.

Terms and refunds · Secure checkout by Stripe · Billed by Nori Software

Not sure where to start? Take the free 10-question check.

All 12 cards

The same signed cards as the trainer above, in one list to read or print.

What decides whether a rated wall is built right?
Whether every component matches the tested design named on the plans: studs, board type and layers, fasteners, insulation and joints.IBC fire-resistance-rated construction chapter, tested assemblies
Do fire walls, fire barriers and fire partitions share one continuity rule?
No. Each has its own rules for how far it extends, where it may stop and how it is supported.IBC fire-resistance-rated construction chapter
Why are some rated walls marked above the ceiling?
So later trades can see the wall is rated and do not cut unprotected openings in it.IBC fire-resistance-rated construction chapter, identification
Right board type, wrong number of layers. Pass or fail?
Fail. The layer count is part of the tested design.IBC fire-resistance-rated construction chapter, tested assemblies
Where do you find the parts list for a rated assembly?
In the listing directory entry for the design number shown in the wall type legend.Listing directory; IBC fire-resistance-rated construction chapter
Fire separation distance is measured to which three lines?
The lot line, the middle of a public way the building faces, or an assumed line between two buildings on the same lot, at right angles to the wall face.IBC definitions and exterior walls chapter
What does final grade have to do at the foundation?
Slope away from it for the distance the code requires, or drain away through swales or drains where that is not possible.IBC soils and foundations chapter, site grading
Worked card (invented): table area 18,000 sq ft, frontage increase 20%. Allowable area?
18,000 + 0.20 × 18,000 = 21,600 sq ft. Compare with the actual area on the plans.IBC building heights and areas chapter (invented values)
What sets a space's occupancy classification?
Its use, not the name of the business in it.IBC use and occupancy classification chapter
What are the three ways to handle mixed occupancies?
Accessory occupancy, nonseparated occupancies (most restrictive rules throughout) and separated occupancies (rated separations).IBC building heights and areas chapter, mixed occupancies
How is area checked for separated occupancies on a story?
Add each occupancy's actual area divided by its allowable area. The sum must not exceed 1.IBC building heights and areas chapter, separated occupancies
What do the A and B in construction types mean?
Levels of protection within a type, A being protected and B unprotected. They are not separate types.IBC types of construction chapter